Strikesorb - 80,40,30

  • Product Code: Raycap
  • Availability: In Stock

STRIKESORB 80:

Strikesorb 80 industrial surge suppression offers unparalleled lightning protection, protecting mission-critical applications from damage caused by lightning surges and other overvoltage events. Even in the most lightning prone environments, Strikesorb 80 lightning surge protectors are capable of absorbing and dissipating the extreme energy of lightning strikes without degradation to the module.

- Innovative design: direct connection, no fuses, environmentally-sealed SPD

- Fully recognized to UL 1449 4th edition

- Compliance to IEC 61643-11

- Maximum Impulse Current (10/350µs) per IEC 61643-11, 25kA

- Maximum Surge Current (8/20µs) per NEMA LS-1, 200kA

- Available in a variety of operating voltages

Voltages

- 120V

- 240V

- 277V

- 400V

- 480V

- 600V

STRIKESORB 40:

Strikesorb 40 surge protection devices protect mission-critical applications from lightning surges and overvoltage events. Even in the most lightning prone environments, Strikesorb 40 surge suppressor modules are capable of absorbing and dissipating the extreme energy of lightning strikes without degradation to the module. Suitable for wind turbine surge protection as well as other applications.

- Innovative design: direct connection, no fuses, environmentally-sealed SPD

- Fully recognized to UL 1449 4th edition

- Compliance to IEC 61643-11

- Maximum surge current (8/20μs) per NEMA LS-1, 140kA

- Maximum impulse current (10/350µs) per IEC 61643-11, 12.5kA

- Available in a variety of operating voltages

Voltages

- 60V

- 120V

- 240V

- 277V

- 400V

- 480V

- 600V

- 1000V

STRIKESORB 30:

The Enhanced Strikesorb 30 SPDs protect mission-critical applications from successive overvoltage events. Strikesorb 30 modules are capable of absorbing and dissipating the energy of multiple electrical surges without degradation to the module. Now, the Strikesorb 30 is suitable for use in locations with both direct or indirect lightning conditions.

- Innovative design: direct connection, no fuses, environmentally-sealed SPD

- Fully recognized to UL 1449 4th edition

- Compliance to IEC 61643-11

- Nominal Discharge Current per UL 1449 4th edition and IEC 61643-11, 20kA

- Impulse Discharge Current (10/350µs) per IEC 61643-11 up to 7.5kA

- Maximum Surge Current (8/20µs) per NEMA LS-1, 60kA

- Available in a variety of operating voltages

Voltages

- 60V

- 120V

- 240V

- 277V

- 400V